Installation
Rack-Mount Subsystem Assembly
16
2 To aide in support bracket installation, remove the rack cabinet side panels.
3 Locate the two support brackets. Mount the two brackets to the rack cabinet
verticals using the four screws, four washers, and four caged nuts provided
for each bracket. Refer to detail “A” in the illustration on the previous page.
NOTE: The caged nuts are secured into the rack cabinet vertical slots by inserting
one side of the nut into the slot and squeezing while pressing the opposite
side in until it snaps into place.
4 Remove the two (2) upper enclosure case screws as depicted below on the
right side of the subsystem cabinet.
NOTE: The enclosure is attached to the support bracket only on the right side.
5 Slide the subsystem cabinet into the cabinet with the subsystem riding on top
of the support brackets.
6 Align the two upper case screw holes with those provided in the support
bracket on the right side.
7 Secure the subsystem cabinet to the right hand rail using the two (2) screws
previously removed.
8 Continue with the component installation on the next page.
Rail is installed to
the front and rear
rack cabinet verticals.
8-32 Pan
Head Screws